表面处理:烤漆、拉丝
Surface Processing: SSS,BK
外形及功能
单舌水平式推杠锁, 广泛应用于防火逃生门, 外形美观性能优越, 适用于安全性
要求较高的场所
订购资料 Order Information
Shape and function:
Single cam horizontal-type push-bar lock.It is universally applied to fire
emergency door.Appearance is beautiful and performance is superior.It is
available for place which has high request on safety.
Application Range:
Widely used in school,hospital,hotel,ofice building,airport and many kinds of public
architects. Its excellent quality and advanced function makes it become an inevitable
product of safety device.
Open Direction: Fire door lock open outside
Form: Single open and double open used together
Open Method: If the door pushed on the right side, it is right open, otherwise, it is left
open.
When the latch is opened, the deadlatch will be automatically compressed, protecting
the floor from damaging.
应用范围:
广泛用于学校、医院、宾馆、写字楼、机场及各种公共建筑。
其优良的品质和完善的功能,使其成为安全装置必不可少的产品。
开门方向:防火门锁一律外开
形式:单开和双开配合使用
开门方式:推出门扇在右为右开,在左为左开
天地拴开启后,拴舌为自动收缩,不会损坏地面
Installation Steps:
1. First of all, mark on the lock screw hole and location. Lock case length is up to door width.
(Attention: Lock case must be installed on the horizontal plane.)
2. Upper seal plate and lock case must be vertical to central line, installed on door latch. Lock
box is installed under the upper seal plate, around 2mm distance.
3. Install pipe and lock box, then connect fork with lock case. Test upper lock latch's
performance, adjust the position of pipe and threaded rod. Install other accessories when
performance works well.
4. The lower lock box is installed on the lower side of the door, lower steel connect testing
performance, fix the threaded rod and directly go into the floor hole. Use threaded rod to
adjust. After adjusting, Test its performance. Lastly bend the split pin a little bit.
5. Use sealing plate to fix the lower fixed link on the floor, then install the pad.
6. Last testing: Gently press lock case, door opening pipe will be automatically shrinked, that
means door opens. When the door
returns to its original place,pipe will automatically stretch out and regain closing status.
7. Debug after installation: It can be opened when press it gently. When the door is open, the
latch of upper and lower lock box can be automatically compressed, and that is normal.